Richmond water heater pilot light won - Access the pilot light: Depending on the model of your water heater, you may need to remove a metal panel to access the pilot light. Once you have access, locate the pilot light and the reset button. Press the reset button: Press and hold the reset button for 30-60 seconds.

 
For use on GE, Rheem, Ruud and Richmond FVIR water heaters with Delta/SIT gas valves; Genuine OEM replacement part; 1 year limited warranty; Fix your water heater with peace of mind using genuine Rheem parts; Easy to install; Call 1-800-432-8373 to ensure this is the correct part for your water heater; Durable construction for long life . Atandt u verse customer service

A thermocouple is a function on your water heater that senses the heat on the pilot light and allows gas to flow to the burner. A bad thermocouple will shut off gas to both the pilot and the burner, which is when people notice that the water heater pilot light is out. Your water heater pilot light works in concert with other parts.I am posting this video as there are many videos on YouTube explaining what to do if your pilot light doesn't remain on after igniting, but couldn't find a v...Feb 9, 2022 · Depending on the water heater you have, it may use an igniter to ignite the gas.When you hold down the pilot switch on a gas heater and click the igniter button repeatedly, a small spark should ignite the pilot.However, if the pilot flame will not light after you click the igniter, you need to verify that a spark is happening inside the pilot.When the piezo igniter is pressed down and released ... No hot water? If the pilot flame in your water heater keeps on going out or won't stay lit, then it could be a problem with the thermocouple or thermal cutof...Replaced Pilot assembly last week as pilot went out when burner shut off. Today I replaced the temperature control valve. Same thing, lit pilot, burner came on the after a heat cycle burner shut off as well as pilot. Trying an immediate restart only igniter worked after about 4 or 5 minutes was able to light the pilot. Then the whole episode ...Jan 24, 2023 · January 24, 2023 by David. We’ll cover the following problems in this complete Richmond water heater troubleshooting guide: Condensation. Yellow soot. The main burner won’t light or stay lit. The pilot light won’t stay lit. Rumbling noise. Noise from the relief valve. No hot water or inadequate hot water. my water heater won't stay onReview Hoffmann Brothers' guide for how to light your water heater pilot light, perform basic checks, troubleshoot and access info for your specific brand. Careers (314) 664-3011 Book Now Air Conditioning Mar 12, 2023 · It’s also a relatively inexpensive component. So, you won’t have to break the bank to replace it. You can check out our guide on why Richmond water heater pilot light won’t stay lit where we have broken down how to replace the thermocouple in nice and easy steps. 6. Faulty Pressure Switch Feb 9, 2022 · Depending on the water heater you have, it may use an igniter to ignite the gas.When you hold down the pilot switch on a gas heater and click the igniter button repeatedly, a small spark should ignite the pilot.However, if the pilot flame will not light after you click the igniter, you need to verify that a spark is happening inside the pilot.When the piezo igniter is pressed down and released ... my water heater won't stay onNov 18, 2022 · The pilot light is an essential part of your Rheem water heater. If it goes out, your water heater wont provide any heat because the pilot light wont ignite the gas to power the heater. This means that you wont be able to light your pilot light. One potential cause of this issue is that you have a blocked gas line. I had a power outage at my house and coincidentally (?) my water heater pilot light went out. My Kenmore water heater is controlled by the Honeywell Gas Valve (part # 9007884), which contains the WV8840 Communication Port. The water heater wouldn’t re-light, but I noticed that the indicator was blinking four times in succession.Oct 19, 2013 · I am posting this video as there are many videos on YouTube explaining what to do if your pilot light doesn't remain on after igniting, but couldn't find a v... Sep 4, 2022 · About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ... Apr 25, 2010 · I could have found the troubleshooting guide by myself. If you replaced the thermocouple and it will not stay lit there are a couple of possibilities. Make sure the pilot flame envelops approximately 3/8 inch of the tip of the new thermocouple. When you go to light make sure you continue to hold down the button at least 30 seconds after the ... Mar 20, 2022 · The article discusses the common problems that may arise with the Richmond water heater and their troubleshooting. These issues include condensation, yellow flame or soot, failure to light the main burner, rumbling noise, relief valve making popping noise, insufficient or no hot water, and too hot water. The reasons behind each issue and their solutions are elaborated upon in the article. So I have a 40 gal Richmond power vent lp water heater. Problem is it doesn't restart So far I have replaced the igniter .I took out the whole water heat and cleaned out the combustion chamber and …It's easy to fix this water heater problem by yourself. I fixed mine and also decided to make a better video to help out more people who love DIY.- Pilot lig...Step 03 – Drain The Tank. Before taking off the gas valve, you need to drain the water heater. Otherwise, you’ll end up with a mess on your hands. The hot water can also cause scalding. Turn off the cold water shutoff valve if you can locate it or shut off the water supply to your entire house.Review Hoffmann Brothers' guide for how to light your water heater pilot light, perform basic checks, troubleshoot and access info for your specific brand. Careers (314) 664-3011 Book Now Air ConditioningThe pilot on my Rheem furnace will not stay lit. I have replaced the thermocouple to no avail. The flame looks perfect, nice and blue, the thermocouple gets glowing hot when attempting to light the pilot. I hold the button down in excess of 3 minutes and as soon as you release, the pilot light goes out immediatly.My seven year old Richmond 6G40-32PF1 lp gas water heater pilot light won’t stay lit after releasing button. The gas tank ran out of gas and was refilled. It is a sealed system with a window to view the pilot light.Pilot light won’t stay lit I had the same problem and placed a small fan in the attic next to the water heater 3 weeks ago and it’s worked so far, Temps in Houston in July are way above 100 degrees in the attic and the problem seems to occur when the outdoor temps are in the mid to high 90’s.Reignite the pilot light. Richmond gas heaters use a pilot light to ignite the gas heating the water. Make sure the light hasn't blown out, and if it has, use the ignition mechanism on the heater to light the pilot. Drain and clean the heater. Follow the instructions in Section 2 for draining your Richmond heater and clean the tank and all ... A water heater pilot light that won’t stay lit is almost always caused by a bad thermocouple. It fails to send a signal to the gas valve to open up, meaning gas does no flow to the pilot and burner. It could also be caused by a faulty gas control valve or tripped thermal switch. If your water heater pilot won’t stay lit even after replacing ... Remove the access panel to access the burner. Turn the knob to “Pilot” to start the flow of gas. You’ll want to press and hold the knob down. While still holding the gas knob, light the pilot with a long lighter. If your gas water heater has an igniting button, press that instead. Once ignited, release and turn the gas knob to the “On ...Oct 19, 2013 · I am posting this video as there are many videos on YouTube explaining what to do if your pilot light doesn't remain on after igniting, but couldn't find a v... If the water heater pilot light will not stay lid there are two main options, the first one is the Thermocouple, but if this one is working fine and you can ... A water heater pilot light that won’t stay lit is almost always caused by a bad thermocouple. It fails to send a signal to the gas valve to open up, meaning gas does no flow to the pilot and burner. It could also be caused by a faulty gas control valve or tripped thermal switch. If your water heater pilot won’t stay lit even after replacing ... The water heater pilot light is a small flame that ignites the gas burner on your water heater. When the water heater pilot light goes out, first try relighting it, following the directions on the water heater label. If the pilot doesn’t relight, if it goes out right after lighting or if it goes out repeatedly, by far the most common cause is ... It is more than likely some kind of high limit sensor which would kick the pilot out should the water heater overheat. If your pilot is not staying lit with a new thermocouple, it may be this sensor. Try jumping the 2 leads going to the thermocouple adapter and see if it remains lit. If it does, it is this sensor that is bad.Meet the Most Efficient Water Heater Available Richmond Hybrid Electric Water Heaters Learn More ... Most efficient water heater available – with up to $5,000 in ...Begin by turning your pilot light off, if it is not already. Next, turn off the flow of gas to your furnace completely using the shutoff valve. It should be nearby or even on your furnace. Once you have done this, allow your furnace to cool down for at least 30 minutes so it is safe to open, then open the hatch covering your pilot light and ...By Vikram May 7, 2023 If you have a Richmond water heater model 6G40-36F3 and you notice that the pilot light won’t stay lit, you may be wondering what is causing this problem and how to fix it. In this blog post, we will explain some of the possible reasons why your pilot light keeps going out and what you can do to solve them.Richmond Water Heater Thermocouple Replacement: The How-To Steps. First off, determine which size and style of thermocouple you need for your Richmond water heater. Once you get the correct thermocouple for your water heater, follow the below step-by-step guide to replace the old thermocouple with a new one. 01. Shut Off The Gas SupplyDec 31, 2015 · 2. If I understand correctly, your pilot flame is lighting correctly. But the main burner won't turn on because the electronics in the Gas Control Valve don't acknowledge the pilot is lit. There are two likely faults: Thermopile is not sensing the flame correctly, or. Circuit Board in the Gas Control Valve is defective. May 7, 2023 · If you have a Richmond water heater model 6G40-36F3 and you notice that the pilot light won't stay lit, you may be wondering what is causing this problem and how to fix it. In this blog post, we will explain some of the possible reasons why your pilot light keeps going out and what you can do to solve them. Mar 1, 2010 · hayewe farm · #2 · Mar 1, 2010. Go to your local hardware or computer store and pick up a can of air used to clean computer keyboards. With the pilot off insert the air can tube in the end of the pilot tube and give it a couple of blasts of air. It may be you have an oxygen depletion unit that is dirty. I had a power outage at my house and coincidentally (?) my water heater pilot light went out. My Kenmore water heater is controlled by the Honeywell Gas Valve (part # 9007884), which contains the WV8840 Communication Port. The water heater wouldn’t re-light, but I noticed that the indicator was blinking four times in succession. Step #3: While holding the knob, press the piezo igniter button at the same time. Keep pressing both buttons until the status light starts blinking. Step #4: Take a look at the viewport to see if the pilot light comes on. If yes, release the valve and set the knob to your desired temperature setting.A.O. Smith GVR 40 101 water heater had no spark on the pilot. Disassembled and cleaned the pilot light and thermocouple. Reassembled and fired it up on the f...01 - Water Heater Gas Valve and Thermostat Assembly. The gas valve opens to allow gas to enter the burner. If the gas valve does not open, the burner will not light. First, ensure that the ignition source is working properly. Second, ensure that the gas valve has pressure. If the ignition source is working, and the gas valve has pressure ...My seven year old Richmond 6G40-32PF1 lp gas water heater pilot light won’t stay lit after releasing button. The gas tank ran out of gas and was refilled. It is a sealed system with a window to view the pilot light.If your pilot light on your Richmond water heater won’t stay lit, it’s usually due to a faulty thermocouple or a lack of combustible air. A problem with the thermocouple is significantly more common, but both could be causing problems. Today, we’ll examine why your water heater pilot light keeps going out and discuss ways you can fix it. Dec 22, 2022 · Pilot light won't stay lit. Richmond 6G40-36F3 Installed 7/2021. ... My seven year old Richmond 6G40-32PF1 lp gas water heater pilot light won't stay lit after ... I am not a professional, just documenting how i repaired the hot water heater's pilot light to stay on. The solution was adjusting the thermocouple. You can ...Sep 3, 2018 · I have a Richmond tankless water heater Model # RMTG-74PVN-1. I have a Richmond tankless water heater Model # XXXXX It was installed the summer of 2007. has operated proplem free until last week when it stopped working and flashing C7 on the remote. Jan 15, 2023 · Step 03 – Drain The Tank. Before taking off the gas valve, you need to drain the water heater. Otherwise, you’ll end up with a mess on your hands. The hot water can also cause scalding. Turn off the cold water shutoff valve if you can locate it or shut off the water supply to your entire house. Jun 26, 2007 · I've got a Richmond Water heater in a 2-flat that is giving me problems. A day ago I got a call that the water wasn't hot anymore so I went over to check it out. The pilot light was out so I lit it by holding down the button and hitting the piezo button. After a few clicks it lit up and stayed lit. Oct 12, 2019 · Hi Ellen I have a Richmond 6G30-32F1 gas hot water heater. that stopped working Thursday. the pilot was out so i lit it and tried to turn it on and everytime i tried to turn it on ot wou;d flameup then blow out. so Ive seen this before so I replavedf the thermocouplet/ mo problem. i tried to turn it on and it flamdd uo ran for aminute then cuts off it keeps dpoing this. what is my next step to try Feb 9, 2022 · Depending on the water heater you have, it may use an igniter to ignite the gas.When you hold down the pilot switch on a gas heater and click the igniter button repeatedly, a small spark should ignite the pilot.However, if the pilot flame will not light after you click the igniter, you need to verify that a spark is happening inside the pilot.When the piezo igniter is pressed down and released ... Richmond water heater pilot light. Water heater thermocouple. How to bypass thermocouple. Richmond water heater pilot won't stay lit. Water heater pilot ligh...Hi Ellen I have a Richmond 6G30-32F1 gas hot water heater. that stopped working Thursday. the pilot was out so i lit it and tried to turn it on and everytime i tried to turn it on ot wou;d flameup the …We have a Rheem gas water heater model number 21V40-7P. We've just gotten the gas tank refilled, but for some reason, the pilot light went out this morning and the water heater is leaking. I'm trying … read moreA.O. Smith GVR 40 101 water heater had no spark on the pilot. Disassembled and cleaned the pilot light and thermocouple. Reassembled and fired it up on the f...Richmond Water Heater Thermocouple Replacement: The How-To Steps. First off, determine which size and style of thermocouple you need for your Richmond water heater. Once you get the correct thermocouple for your water heater, follow the below step-by-step guide to replace the old thermocouple with a new one. 01. Shut Off The Gas SupplyFeb 15, 2021 · If your hot water heater has no spark at all, or the flame isn't staying on, give this video a watch for a couple super simple things to try. Repairing your ... Slightly depress the gas control knob and turn clockwise to OFF position. Wait 5 minutes to clear out any gas. Stop and follow the safety precautions as above if you smell any gas. Go to the next step if you do not smell gas. Remove the outer door from the water heater. Do not attempt to remove the inner door.Water heater pilot is not on; no hot water. Serial No. Q132038894. Model No. 6G40-36F3. I've tried to start the pilot light without success. The instructions affixed on the heater and the instructions for lighting do not match my heater: I see no door to open; no place to see the pilot to determine if it's lit The article discusses the common problems that may arise with the Richmond water heater and their troubleshooting. These issues include condensation, yellow flame or soot, failure to light the main burner, rumbling noise, relief valve making popping noise, insufficient or no hot water, and too hot water. The reasons behind each issue and their solutions are elaborated upon in the article.Nov 28, 2009 · RickyM1118. Plumber. High School or GED. 29 satisfied customers. My seven year old Richmond 6G40-32PF1 lp gas water heater. My seven year old Richmond 6G40-32PF1 lp gas water heater pilot light won't stay lit after releasing button. The gas tank ran out of gas and was … read more. I'm not a professional. This is the one thing that's worked AMAZING to get my hot water heater pilot light to stay on! INCREDIBLE prices on AMAZON: https://a...Oct 12, 2019 · Hi Ellen I have a Richmond 6G30-32F1 gas hot water heater. that stopped working Thursday. the pilot was out so i lit it and tried to turn it on and everytime i tried to turn it on ot wou;d flameup then blow out. so Ive seen this before so I replavedf the thermocouplet/ mo problem. i tried to turn it on and it flamdd uo ran for aminute then cuts off it keeps dpoing this. what is my next step to try 5. Flex Tube Defects. This also another possible reason why your pilot’s light won’t come on. The flex tube is how the gas reaches the device, and if the continuous flow of gas is interrupted, the pilot light won’t stay lit. This usually happens when the tube is kinked at one or many points.No hot water? If the pilot flame in your water heater keeps on going out or won't stay lit, then it could be a problem with the thermocouple or thermal cutof...Sep 3, 2018 · I have a Richmond tankless water heater Model # RMTG-74PVN-1. I have a Richmond tankless water heater Model # XXXXX It was installed the summer of 2007. has operated proplem free until last week when it stopped working and flashing C7 on the remote. Last night, I noticed that the pilot light was out and this morning when the plumber came to look at it he immediately told me what was wrong with it which is the gas control valve is bad. Said it would cost about $700 to fix so I called Menards and the plumbing associate informed me that the Richmond water heaters have a recall on them for ...Press and hold down the button. Listen for the click and ignition. Your igniter should light the gas directly if it is a hot surface ignition. You will know it is working if you feel the heat coming from the unit. Lighting an intermittent pilot ignition: Locate the igniter button and knob.Apr 9, 2020 · I'm not a professional. This is the one thing that's worked AMAZING to get my hot water heater pilot light to stay on! INCREDIBLE prices on AMAZON: https://a... You can easily determine whether the gas valve of Richmond Water Heater gets bad or not by lighting the pilot and testing the thermocouple. Let’s start with lighting the pilot. Follow the manual and attempt to light the pilot. Press the pilot knob all the way down and keep pressing the igniter button. If the pilot light doesn’t come on ...Clean those first before doing anything else. It's routine maintenance that needs to be done in any case. You need to remove the pilot burner, take the pilot tubing off and remove the pilot orifice. Sometimes you can clean the pilot orifice with the wire from a wire brush. Use a wire brush to clean the pilot burner.Pilot light won't stay lit when you turn knob from pilot to on, it goes out as soon as the knob pops up before you can turn it to on. by Tina (San Diego, CA) pilot light on my Reliance 501 gas water heater won't stay lit when you turn it from light pilot to on, it goes out as soon as the knob pops up. What do I do?Begin by turning your pilot light off, if it is not already. Next, turn off the flow of gas to your furnace completely using the shutoff valve. It should be nearby or even on your furnace. Once you have done this, allow your furnace to cool down for at least 30 minutes so it is safe to open, then open the hatch covering your pilot light and ...A thermocouple is a function on your water heater that senses the heat on the pilot light and allows gas to flow to the burner. A bad thermocouple will shut off gas to both the pilot and the burner, which is when people notice that the water heater pilot light is out. Your water heater pilot light works in concert with other parts.Replace the pilot assembly, I do water heater repair, that unit is actually made by A.O. Smith. It’s got a 180 pilot assembly. There is a little round disc that is in the line from the thermocouple that is probably bad and it won’t let the circuit complete.Mar 1, 2010 · hayewe farm · #2 · Mar 1, 2010. Go to your local hardware or computer store and pick up a can of air used to clean computer keyboards. With the pilot off insert the air can tube in the end of the pilot tube and give it a couple of blasts of air. It may be you have an oxygen depletion unit that is dirty. Mar 20, 2022 · The article discusses the common problems that may arise with the Richmond water heater and their troubleshooting. These issues include condensation, yellow flame or soot, failure to light the main burner, rumbling noise, relief valve making popping noise, insufficient or no hot water, and too hot water. The reasons behind each issue and their solutions are elaborated upon in the article. The water heater pilot light is a small flame that ignites the gas burner on your water heater. When the water heater pilot light goes out, first try relighting it, following the directions on the water heater label. If the pilot doesn’t relight, if it goes out right after lighting or if it goes out repeatedly, by far the most common cause is ... It's easy to fix this water heater problem by yourself. I fixed mine and also decided to make a better video to help out more people who love DIY.- Pilot lig...For use on GE, Rheem, Ruud and Richmond FVIR water heaters with Delta/SIT gas valves; Genuine OEM replacement part; 1 year limited warranty; Fix your water heater with peace of mind using genuine Rheem parts; Easy to install; Call 1-800-432-8373 to ensure this is the correct part for your water heater; Durable construction for long lifeThe pilot on my Rheem furnace will not stay lit. I have replaced the thermocouple to no avail. The flame looks perfect, nice and blue, the thermocouple gets glowing hot when attempting to light the pilot. I hold the button down in excess of 3 minutes and as soon as you release, the pilot light goes out immediatly.The pilot on my Rheem furnace will not stay lit. I have replaced the thermocouple to no avail. The flame looks perfect, nice and blue, the thermocouple gets glowing hot when attempting to light the pilot. I hold the button down in excess of 3 minutes and as soon as you release, the pilot light goes out immediatly.Replaced Pilot assembly last week as pilot went out when burner shut off. Today I replaced the temperature control valve. Same thing, lit pilot, burner came on the after a heat cycle burner shut off as well as pilot. Trying an immediate restart only igniter worked after about 4 or 5 minutes was able to light the pilot. Then the whole episode ...If the water heater pilot light will not stay lid there are two main options, the first one is the Thermocouple, but if this one is working fine and you can ...

A water heater pilot light that won’t stay lit is almost always caused by a bad thermocouple. It fails to send a signal to the gas valve to open up, meaning gas does no flow to the pilot and burner. It could also be caused by a faulty gas control valve or tripped thermal switch. If your water heater pilot won’t stay lit even after replacing ... . Free fedex alert signature req

richmond water heater pilot light won

The pilot on my Rheem furnace will not stay lit. I have replaced the thermocouple to no avail. The flame looks perfect, nice and blue, the thermocouple gets glowing hot when attempting to light the pilot. I hold the button down in excess of 3 minutes and as soon as you release, the pilot light goes out immediatly.hayewe farm · #2 · Mar 1, 2010. Go to your local hardware or computer store and pick up a can of air used to clean computer keyboards. With the pilot off insert the air can tube in the end of the pilot tube and give it a couple of blasts of air. It may be you have an oxygen depletion unit that is dirty.Jan 17, 2021 · I installed a new Richmond water heater and worked good for like 4 - 5 days. then pilot light went and when i would try to ignite, pilot light would light but as soon as i replaced thermocoupler did t … read more Review Hoffmann Brothers' guide for how to light your water heater pilot light, perform basic checks, troubleshoot and access info for your specific brand. Careers (314) 664-3011 Book Now Air ConditioningIf the water heater pilot light will not stay lid there are two main options, the first one is the Thermocouple, but if this one is working fine and you can ... If your gas water heater doesn’t stay lit, you may have a defective thermocouple. Most gas fired water heaters use a standing pilot to ignite the main burner. The gas for the pilot assembly is supplied by the main gas valve and is monitored by the thermocouple. The thermocouple is a heat sensing probe that is part of the pilot assembly and ...Feb 14, 2019 · A.O. Smith GVR 40 101 water heater had no spark on the pilot. Disassembled and cleaned the pilot light and thermocouple. Reassembled and fired it up on the f... If the water heater pilot light will not stay lid there are two main options, the first one is the Thermocouple, but if this one is working fine and you can ... Jan 24, 2023 · January 24, 2023 by David. We’ll cover the following problems in this complete Richmond water heater troubleshooting guide: Condensation. Yellow soot. The main burner won’t light or stay lit. The pilot light won’t stay lit. Rumbling noise. Noise from the relief valve. No hot water or inadequate hot water. May 5, 2022 · I have a Richmond hot water heater with a Honeywell S8610U controller and a Honeywell VR8245M gas valve. The ignition sequence seams to start normally- pilot ignition, main burner ignition- then the m … I have a Richmond tankless water heater Model # RMTG-74PVN-1. I have a Richmond tankless water heater Model # XXXXX It was installed the summer of 2007. has operated proplem free until last week when it stopped working and flashing C7 on the remote.By Vikram May 7, 2023 If you have a Richmond water heater model 6G40-36F3 and you notice that the pilot light won’t stay lit, you may be wondering what is causing this problem and how to fix it. In this blog post, we will explain some of the possible reasons why your pilot light keeps going out and what you can do to solve them.Have you tried cleaning/replacing your thermocouple and still no dice? Have you tried cleaning/replacing the pilot assembly and still nothing? My opinion is ...If the pilot won't stay lit after you release the button/knob you hold down to light it then the first thing that needs to be done is to replace the pilot flame sensor, thermocouple (heavy bare copper wire connected to the gas valve) or the thermopile (small shielded cable with 2 wires connected to the gas valve).Jun 26, 2007 · I've got a Richmond Water heater in a 2-flat that is giving me problems. A day ago I got a call that the water wasn't hot anymore so I went over to check it out. The pilot light was out so I lit it by holding down the button and hitting the piezo button. After a few clicks it lit up and stayed lit. Reignite the pilot light. Richmond gas heaters use a pilot light to ignite the gas heating the water. Make sure the light hasn't blown out, and if it has, use the ignition mechanism on the heater to light the pilot. Drain and clean the heater. Follow the instructions in Section 2 for draining your Richmond heater and clean the tank and all ...Jun 15, 2017 · So I have a 40 gal Richmond power vent lp water heater. Problem is it doesn't restart So far I have replaced the igniter .I took out the whole water heat and cleaned out the combustion chamber and … The article discusses the common problems that may arise with the Richmond water heater and their troubleshooting. These issues include condensation, yellow flame or soot, failure to light the main burner, rumbling noise, relief valve making popping noise, insufficient or no hot water, and too hot water. The reasons behind each issue and their solutions are elaborated upon in the article..

Popular Topics